Oil and Petrol Separators
Use
The Hydrocarbons enter the trap with water.
Operations of the Trap
Hydrocarbons enter the trap with water. They strike the plate and this releases hydrocarbon globules which then float to the surface. Heavier silt and sludge sinks to the bottom of the trap. Most suspended solids will sink to the bottom of the trap as they absorb water and become heavier. The last compartment at the outlet allows only grey water to return to the waste water systems.
Fitting Units
The unit can be fitted into a space 75mm wider than the actual Separator.
Manufactured
Stainless Steel A1S1304 with pedestrian aluminium durbar lid. Screw fixed Stainless Steel screws.
(Heavier duty lids of galvanised mild steel on request).
Adjustments (extra cost in 100mm pedestrian increments)
Increase the T size or invert level to ensure the lid is at the finished ground level and the pipe meets the existing invert datum.
|
Separator UG4OP |
Capacity
Ltrs |
Inlet |
Outlet |
775 |
110mm |
110mm |
|
|
|
|
|
|
Separator UG3OP |
Capacity
Ltrs |
Inlet |
Outlet |
355 |
110mm |
110mm |
|
|
|
|
|
|
Oil Separators with Coalescent Filter
|
Oil Separator UG6CF |
Capacity
Ltrs |
Inlet |
Outlet |
804 |
110mm |
110mm |
|
|
|
|
|
|
Oil Separator UG5CF |
Capacity
Ltrs |
Inlet |
Outlet |
542 |
110mm |
110mm |
|
|
|
|
|
|
|
|
Standard inlet/outlet 110mm. 150mm – 200mm available on request.
|
|
Contact Aluline for FREE comprehensive operating instructions and advice. |